BXGMZ - AROCLOR 1242, 48585
- MSDS: BXGMZ
- Manufacturer: SUPELCO INC
- Product Name: AROCLOR 1242, 48585
- National Stock Number: 6810-00N059174
Product Identification
Product ID:AROCLOR 1242, 48585
MSDS Date:01/04/1990
FSC:6810
NIIN:00N059174
MSDS Number: BXGMZ
Responsible Party
BELLEFONTE, PA 16823-0048
US
Emergency Phone: 814-359-3441
Info Phone: 814-359-3441
Cage: 54968
Contractor
Telephone: 314-771-5765/414-273-3850X5996
Cage: 54968
Ingredients
POLYCHLORINATED BIPHENYL (AROCLOR 1242); (AROCHLOR 1242)
CAS: 53469-21-9
RTECS: TQ1356000
OSHA PEL S, 1 MG/M3
ACGIH TLV: S, 1 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:LD50(ORAL,RAT):4250 MG/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:MAY IRRITATE EYES AND/OR SKIN.
IRRITATES SKIN, DERMATITIS, LIVER DAMAGE.
Explanation of Carcinogenicity:AROCLOR 1242(POLYCHLORINATED
BIPHENYL-PCB): IARC GROUP 2A, SUPP 7, P 322, 1984; ANTICIPATED
CARCINOGEN, NTP 7TH ANN RPT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH W/WATER FOR AT LST 15 MINS. CONT MD.
PETROLATUM-BASED OPHTHALMIC OINTMENT MAY BE APPLIED TO EYES TO
RELIEVE IRRIT. SKIN:FLUSH W/LG VOLS OF WATER. INHAL:IMMED MOVE TO
FRESH AIR. INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON.
NEVER TRY TO MAKE AN UNCON PERSON VOMIT. DO NOT INDUCE VOMITING.
CONTACT A PHYSICIAN.
Fire Fighting
Extinguishing Media:THIS MATERIAL IS NOT FLAMMABLE. DETERMINED BY
SUPPORTING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THE FOLLOWING TOXIC VAPORS ARE FORMED
WHEN THIS MATERIAL IS HEATED TO DECOMPOSITION. HCL.
Accidental Release
Spill Release Procedures:CLEAN AREA WITH SOAP AND WATER. TAKE UP WITH
ABSORBENT MATERIAL. VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN SEALED CONTAINER IN COOL, DRY
LOCATION. THIS MATERIAL IS INTENDED FOR R&D USE ONLY AND MAY NOT BE
USED FOR DRUG, HOUSEHOLD OR OTHER PURPOSES.
Other Precautions:POSSIBLE CANCER HAZARD. AVOID EYE OR SKIN CONTACT.
AVOID BREATHING VAPORS.
Exposure Controls
Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATORY PROTECTION.
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:554F,290C
Spec Gravity:1.3 (WATER=1)
Appearance and Odor:CLEAR VISCOUS LIQUID TO STICKY SOLID.
Stability
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:HCL
Disposal
Waste Disposal Methods:COMPLY WITH ALL APPLICABLE FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.